5 Installing the clip nuts
1. Clip nut location
2. Rail screw location
3. Bottom of the library
4. Rack markers spaced 1U apart
On the front of the rack, insert two clip nuts on each
side in the locations shown. These will be used to
secure the library to the rack.
6 Installing the library
Slide the library onto the rails. Secure the front bezel
to the rack using a #2 Phillips screwdriver placed
through the small holes in the mounting bracket to
tighten the three captive screws on each side of the
library.
Optional: Adding a power supply
With the redundant power supply upgrade kit, the
library will continue to operate without interruption if
either power supply or AC power source fails.
To install the redundant power supply, remove the
cover plate for the redundant power supply using a
#2 Phillips screwdriver. Slide the power supply into
the bay until it is firmly seated. Tighten the three blue
thumbscrews with your fingers to secure the power
supply.