HP StorageWorks MSL4048 Tape Library firmware release notes Firmware version 6.50 (AK380-96005, August 11, 2008)
inamailslotthatwasputtherebythatlogicallibrary. TheSCSIACCESSbitnowaccurately
reflects this permission.
• Fixed a rare condition when the OCP would continue to show <-Close Mailslot when the
mailslot was closed. Pressing the front panel buttons would not cause a change in the display.
• Fixed a case where the Library could appear unresponsive when used with network security
programs that constantly check the security status of all network ports. Usually Drive
Communication (code: F1 xx) errors wer e the last entries in the library logs.
• Fixed a case where the Library could appear unresponsive after the operator issued a command
fromtheOCPtoremoveamagazinebutthemagazinewasnotremoved.
• Fixed a case where the time stamp in the library logs would be recorded as one day earlier
than the library time.
• Fixed a case where error retr y Code 88 00 (set ting of sled motor parameters failed) was
incorrectly logged during the power up sequence.
• Fixed a case where error c ode 9 B (sle d p osition sensor n ot found) was reported at ambient
temperatures below 10 C when the mailslot did not pop out more than 15 mm.
• Fixed a case where the Library would report N ot Ready a fter running the Demo Test.
Compatibility note
When using this firmware version (6.50) or future rev isions with the Encryption Kit, any key server tokens
set with an o dd number of characters for the PIN will not be totally backwards compatible in Autoloaders
or Librar
ies with code revisions 2.10, 4.00, 6.30, or 8.70 (the previous released versions). In those
cases, a token in an Autoloader or Library with 2.10, 4.00, 6.30, or 8.70 firmware revisions will be
able to accept the PIN for the token and access keys on the token, but the user will not be able to
change th
ePINonthetoken,savethekeystoafile, or restore the keys from a file until the Autoloader
or Libra
ry firmware is upgraded. Users should always upgrade to the latest version of firmware to
ensure complete compatibility.
Installation instructions
To upgrade firmw are from the RMI:
1. Download current firmware using HP Library & Tape Tools or from the HP support website:
h
ttp://www.hp.com /support/storage .
2. Log into the RMI as the administrator user.
3. In the Support: Firmware page, browse to the location of the Library firmw are file.
4. Cli ck Update.
To upgrade firmware from the OCP using a USB flash drive:
1. Download current firmware using HP Library & Tape Tools or from the HP support website:
h
ttp://www.hp.com /support/storage .Copythefirmware onto the USB flash drive.
2. Insert the USB flash d rive into the USB port on the back of the Library.
3. From the Support menu, select FW Upgrade > By USB.
4. Select the Library as the target for the upgrade, and select the filename of the firmw ar e.
5. Click Upgrade.
6. When the upgrade is complete, remove the USB flash drive from the USB port.
De
termining current version
To
find the version of firmware installed on the Library, see the RMI Supp ort: Firmware screen or the O CP