HP StorageWorks MSL8096 Tape Library firmware release notes Version 8.70 (AK382-96005, July 7, 2008)

Description
This release includes updated rmware for the HP StorageWorks MSL8096 Tape Library.
The Library rmware can be updated through any of the following methods:
Remote management interface (RMI) .
Operator co
ntrol p anel (OCP) .
HP Library and Tape Tools (L&TT).
Library rmware version
8.70
Update recommendation Recommended
Supersedes All earlier versions of Library rmwar e.
Product models
All HP StorageWorks MSL8096 Tape Libraries.
Languages
English (American)
English (International)
Enhancements
Support added for Internet Protocol version 6 (IPv6).
Support added for pa r titioning the Library into logical libraries. The Tape Library can have up to
as many logical libraries as there are tape driv es.
Support added for the 1/8 G2 and MSL Encryption Kit, which is a solution for generating and
storing encryption keys to write and restore encrypted data on LTO-4 media with LTO-4 tape drives.
Support added for the Ultrium 1760 pa rallel SCSI h alf-height tape drive.
Support added for SNMP version 2.
Ability to save and restore the Library conguration settings to a USB ash drive (from the OCP)
or a le (from the RMI).
Thenumberofallowedreservedslotsisincreasedfrom36to94.
Fixes
Fixed a case where the Library could appear unresponsive when used with network security
programs that constantly check the security status of all network ports. Usually Drive
Commu
nication (code: F1 xx) errors were the last entries in the library logs.
Fixed a case where the Library could appea r unresponsive after the operator issued a command
from the OCP to remove a magazine b ut the magazine was not removed.
Fixe
dacasewherethetimestampinthelibrarylogswouldberecordedasonedayearlier
than the lib rary time.
Fixed a case where error retry Code 88 00 (setting of sled motor parameters failed) was
inco
rrectly logged during the power up sequence.
Fixed a case where error cod e 9B (sled position sensor not found) was reported at ambient
temperatures below 10 C when the mailslot did not p o p out m ore than 15 mm.
Fix
ed a case where the Library would report Not Ready after running the Demo Test.
HP StorageWorks MSL8096 Tape Library rmware release notes
3