MSL5000 and 6000 Series Tape Libraries User Guide

Troubleshooting
143HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
200F Removal Prevented
(Receive medium prevent removal from
drive for a fetch.)
Attempt to unload drive from software. If
fails, power off unit, disconnect from SCSI
bus, and retry operation.
Invalid host initiated operation. Check that
application is certified to work with your
library and has up-to-date patches.
Invalid user initiated operation. Select
parameters correctly and try again.
Check for firmware tape in drive.
Check for cleaning tape in drive.
Press the Enter button to clear the
message.
2010 Ctl. Firmware Error
(Internal task processing error. Unexpected
event. SMX send or receive error.)
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power back on.
Upgrade firmware if a newer revision
exists.
2030 Drive Timeout Error
(Cannot communicate with DLT drive.)
Check if the drive shows good status
through the drive status window.
Cycle power to the library or reboot using
the GUI touch screen. Wait 20 seconds to
power back on.
Reseat drive.
2080 Drive Code Update Command
Error
(Update code from SCSI or from tape
failed.)
Make sure that the firmware is the correct
file for this product.
Check if the drive shows good status
through the drive status window.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power back on.
Attempt firmware upgrade again.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP