MSL5000 and 6000 Series Tape Libraries User Guide

Troubleshooting
144 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
2081 Move Command Failure
(Move command from or to drive slot
failed. Detected by control task.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Load/unload a cartridge to the drive to
verify.
2090 Open Mail Slot Fault
(Door open sensor time-out detected when
open door.)
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
2091 Open Left Door Fault
(Door open sensor time-out detected when
open door.)
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
2092 Open Right Door Fault
(Door open sensor time-out detected when
open door.)
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
2093 Open Doors Fault
(Door open sensor time-out detected when
open door.)
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP