MSL5000 and 6000 Series Tape Libraries User Guide
Troubleshooting
147HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
3015 Drive Timeout Failure
(Loader detects unload command
time-out.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat the drive.
■ Load/unload a cartridge to the drive to
verify.
■ Check the tape cartridge used in the last
operation for damage.
■ Run the cartridge cycle diagnostic to
verify.
3016 Drive Status Failure
(Detected drive error from fetch, stow and
wait for handle okay DLT drive operation.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat the drive.
■ Load/unload a cartridge to the drive to
verify.
■ Check the tape cartridge used in the last
operation for damage.
■ Run the cartridge cycle diagnostic to
verify.
3017 Drive In Flux Timeout
(Time-out waiting for drive to clear the full
status.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat the drive.
■ Load/unload a cartridge to the drive to
verify.
■ Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP