MSL5000 and 6000 Series Tape Libraries User Guide

Troubleshooting
147HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
3015 Drive Timeout Failure
(Loader detects unload command
time-out.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
3016 Drive Status Failure
(Detected drive error from fetch, stow and
wait for handle okay DLT drive operation.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
3017 Drive In Flux Timeout
(Time-out waiting for drive to clear the full
status.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP