MSL5000 and 6000 Series Tape Libraries User Guide

Troubleshooting
149HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
301B Drive Communication Error
(Intertask send, receive failed.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
301C Drive Get General Status Fail
(Drive communication failed.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
301D Drive Get Status 3 Fail
Press the Enter button to clear the
message.
Contact support.
3020 Undefined Config
(In loader, unexpected configuration, not a
5U or 10U model. In diagnostics, invalid
source or destination.)
Press the Enter button to clear the
message.
Contact support.
3030 Orphan Cartridge not stowed
(The loader could not successfully stow an
orphan cartridge to a bin.)
Unload magazine, remove a tape, replace
the magazine, and retry the operation.
Table 11: Fault Symptom Codes (Continued)