MSL5000 and 6000 Series Tape Libraries User Guide
Troubleshooting
152 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
305B Diag Fetch, Drive not loaded
(Diag: no cartridge present for fetch.)
■ Press the Enter button to clear the
message.
■ Load a cartridge in the drive and retry the
operation.
■ Invalid user initiated operation. Set
parameters correctly and try again.
305D Diag Timeout waiting for drive
empty, ready
(Fetch, time-out waiting for drive unload.)
■ Press the Enter button to reboot.
■ Invalid user initiated operation. Set
parameters correctly and try again.
■ Ensure the drive shows good status
through the drive status window.
■ Check the tape cartridge used in the last
operation for damage.
305F Invalid bin number
(Invalid bin number detected in diag.)
■ Press the Enter button to clear the
message.
■ Invalid user initiated operation. Set
parameters correctly and try again.
3060 Zone Sequence Error
(Robot did not find sensor on power-up.)
■ Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
3074 Drive 0 Eject Failed
(Eject command time-out.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat drive.
■ Load/unload a cartridge to the drive to
verify.
■ Check the tape cartridge used in the last
operation for damage.
■ Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP