MSL5000 and 6000 Series Tape Libraries User Guide
Troubleshooting
162 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
7009 The opcode for a WORD message
was unknown
■ Press the Enter button to reboot.
■ Cycle power to the library or reboot using
the GUI touch screen.
700A The opcode for a DWORD message
was unknown
■ Press the Enter button to reboot.
■ Cycle power to the library or reboot using
the GUI touch screen.
700B The button causing library to
go offline was unknown
(A command to take the library off-line was
completed successfully, but the GUI button
that initiated the action could not be
identified.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
700C Destination Xchg was Null
■ Press the Enter button to reboot.
■ Cycle power to the library or reboot using
the GUI touch screen.
700D Sending of a cmd failed
■ Press the Enter button to reboot.
■ Cycle power to the library or reboot using
the GUI touch screen.
700E Deactivating a drive that is
not attached
(The control task indicates that a request to
deactivate a drive failed because the drive
is not attached.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window.
■ Reseat the drive.
700F Deactivation of a drive failed
(The control task indicates that a request to
deactivate a drive failed. Reason
unknown.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window
■ Reseat the drive.
7010 Drive removal failed
(The drive task indicates that a request to
power-down a drive failed. Reason
unknown.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP