R2511-HP MSR Router Series Fundamentals Command Reference(V5)
103
• If the detection timer is set to 0, the protocol module never automatically recovers the port. You need
to manually bring up the port by using the undo shutdown command or change the detection timer
to a non-zero value.
Examples
# Set the port status detection timer to 100 seconds.
<Sysname> system-view
[Sysname] shutdown-interval 100
sysname
Use sysname to set the device name.
Use undo sysname to restore the default.
Syntax
sysname sysname
undo sysname
Default
The default name is HP.
Views
System view
Default command level
2: System level
Parameters
sysname: Name of the device, which is a string of 1 to 30 characters.
Usage guidelines
A device name identifies a device in a network and works as the user view prompt at the CLI. For
example, if the device name is Sysname, the user view prompt is <Sysname>.
Examples
# Set the name of the device to R2000.
<Sysname> system-view
[Sysname] sysname R2000
[R2000]
system-failure
Use system-failure to configure the exception handling method.
Use undo system-failure to restore the default.
Syntax
system-failure { maintain | reboot }
undo system-failure
Default