R2511-HP MSR Router Series Fundamentals Command Reference(V5)

105
Command
MSR
900
MSR93
X
MSR20
-1
X
MSR20 MSR30 MSR50
MSR1
000
temperature-li
mit
No No No
Yes
Value range
for
lower-value: 0
to 14
Value range
for
upper-value:
50 to 90
Yes
Value range
for
lower-value: 0
to 14
Value range
for
upper-value:
40 to 90
Yes
Value range
for
lower-value: 0
to 30
Value range
for
upper-value:
40 to 90
No
Examples
# Set the lower temperature threshold for card 1 to 10°C (50°F) and the upper temperature threshold to
75°C (167°F).
<Sysname> system-view
[Sysname] temperature-limit 1 10 75
Setting temperature limit succeeded.
time at
Use time at to add a command to run at a specific time and date in the job schedule.
Use undo time to remove a command from the job schedule.
Syntax
time time-id at time date command command
time time-id { one-off | repeating } at time [ month-date month-day | week-day week-daylist ] command
command
undo time time-id
Views
Job view
Default command level
3: Manage level
Parameters
time timeid: Time setting entry, an integer in the range of 1 to 10.
at time: Specifies an execution time, in the hh:mm format. The hh value is in the range of 0 to 23 and the
mm value is in the range of 0 to 59.
one-off: Specifies that the specified command is executed for once.
repeating: Specifies a recurring time schedule.
date: Specifies an execution date, in the MM/DD/YYYY or YYYY/MM/DD format. The YYYY value is in
the range of 2000 to 2035, the MM value is in the range of 1 to 12, and the DD value is in the range
of 1 to 31. The specified execution date must be ahead of the current date.
month-date month-day: Specifies the date for executing the command. The month-day argument
specifies the date, and is in the range of 1 to 31.