R2511-HP MSR Router Series Fundamentals Command Reference(V5)
67
add: Adds a specified offset to UTC.
minus: Subtracts a specified offset to UTC.
zone-offset: Specifies an offset to the UTC, in the hh:mm:ss format. Zeros can be omitted, unless you
specify 00:00:00.
Usage guidelines
To verify the setting, use the display clock command.
The timestamps in system messages are adjusted in reference to the time zone and daylight saving
schedule.
Examples
# Set the local time zone to add five hours to UTC time.
<Sysname> system-view
[Sysname] clock timezone z5 add 5
Related commands
• clock datetime
• clock summer-time one-off
• clock summer-time repeating
• display clock
configure-user count
Use configure-user count to configure the maximum number of users allowed to enter system view at the
same time.
Use undo configure-user count to restore the default.
Syntax
configure-user count number
undo configure-user count
Views
System view
Default command level
2: System level
Parameters
number: Specifies the maximum number of concurrent users.
Usage guidelines
Two users are allowed to enter system view by default.
When multiple users enter system view to configure certain attribute, the most recent configuration takes
effect.
When the number of users has already reached the limit, other users can not enter system view.
The following table shows the value ranges for the number argument: