R2511-HP MSR Router Series Fundamentals Command Reference(V5)

80
Command MSR900 MSR93
X
MSR20-1
X
MSR20
MSR30
MSR50 MSR1000
display
environment
No No No
Yes
(The cpu
keyword is
not
supported)
Yes
(The cpu
keyword is
not
supported)
Yes
Yes
(The cpu
keyword is
not
supported)
Examples
# Display temperature information.
<Sysname> display environment
System Temperature information (degree centigrade):
----------------------------------------------------
SlotNo Temperature Lower limit Upper limit
0 41 5 60
# Display temperature information for all CPUs.
<Sysname> display environment cpu
CPU Temperature information (degree centigrade):
-------------------------------------------------
SlotNO Temperature Lower limit Upper limit
0 29 12 63
Table 13 Command output
Field Descri
p
tion
System Temperature information
(degree centigrade)
Temperature information of system cards.
CPU Temperature information
(degree centigrade)
Temperature information of cards of the system (degree centigrade).
SlotNO Number of the slot in which the card resides.
Temperature Current temperature.
Lower limit Lower limit of temperature.
Upper limit Upper limit of temperature.
display fan
Use display fan to display the operating states of fans.
Syntax
display fan [ fan-id ] [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
1: Monitor level