R2511-HP MSR Router Series Fundamentals Command Reference(V5)
90
Field Remarks
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error.
Transceiver info checksum error Transceiver information checksum error.
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
The port does not support the transceiver type.
Examples
# Display the alarms present on the transceiver module in interface GigabitEthernet 2/1.
<Sysname> display transceiver alarm interface gigabitethernet 2/1
GigabitEthernet2/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 19 Command output
Field Descri
p
tion
transceiver current alarm information Alarms present on the transceiver module.
RX loss of signal Incoming (RX) signal is lost.
RX power low Incoming (RX) power level is low.
display transceiver diagnosis
Use display transceiver diagnosis to display the measured values of the digital diagnosis parameters for
transceiver modules.
Syntax
display transceiver diagnosis { controller [ controller-type controller-number ] | interface [ interface-type
interface-number ] } [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
2: System level
Parameters
controller [ controller-type controller-number ]: Displays the measured values of the digital diagnosis
parameters for the transceiver module in a controller interface. The controller-type controller-number
argument specifies a controller interface by its type and number. If no controller interface is specified, this
command displays the measured values of the digital diagnosis parameters for transceiver modules in all
controller interfaces.