R2511-HP MSR Router Series High Availability Configuration Guide(V5)
30
• The Negative state of the track entry shows that the object is not available, and the apply clause is
invalid.
• The Invalid state of the track entry shows that the apply clause is valid.
The following objects can be associated with a track entry:
• Outgoing interface.
• Next hop.
• Default outgoing interface.
• Default next hop.
Configuration prerequisites
Before you associate Track with PBR, create a policy or a policy node and configure the match criteria as
well.
Configuration procedure
You can associate a nonexistent track entry with PBR. The association takes effect only after you use the
track command to create the track entry. For more information about PBR, see Layer 3—IP Routing
Configuration Guide.
To associate Track with PBR:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Create a policy or policy
node and enter PBR policy
node view.
policy-based-route policy-name [ deny |
permit ] node node-number
N/A
3. Define a match criterion.
• Define a packet length match criterion:
if-match packet-length min-len max-len
• Define an ACL match criterion:
if-match acl acl-number
Optional.
By default, no packets are
filtered.