R2511-HP MSR Router Series Interface Configuration Guide(V5)

84
If the two POS interfaces are directly connected, verify that the two ends use different clock mode
settings.
If the problem persists, contact HP Support.
Symptom 2
The physical layer is up, but the link is down.
Solution
To resolve the problem:
Verify that the two ends have matching clock mode, scrambling setting, and physical parameters.
Verify that the two ends have the same link layer protocol.
Verify that the two ends are assigned IP addresses.
If the problem persists, contact HP Support.
Symptom 3
A great amount of IP packets are dropped.
Solution
To resolve the problem:
Verify that the correct clock mode is configured on the POS interface.
Incorrect clock mode setting can incur a large amount of CRC errors.
Verify that the two ends have the same MTU setting.
If the problem persists, contact HP Support.