R2511-HP MSR Router Series Layer 2 - WAN Command Reference(V5)
140
Interface Link Protocol Main IP Description
MFR4 UP UP(s) --
# Display the brief information of all MFR interfaces in the DOWN state.
<Sysname> display interface mfr brief down
The brief information of interface(s) under route mode:
Link: ADM - administratively down; Stby - standby
Interface Link Cause
MFR1 DOWN Not connected
Table 28 Command output
Field Descri
p
tion
current state
Physical layer state of the MFR interface:
• DOWN (Administratively)—The interface has been
shut down with the shutdown command.
• DOWN—The interface is physically down but
administratively up.
• UP—The interface is both administratively and
physically up.
Line protocol current state
Link layer state of the MFR interface:
• DOWN—The link layer of the interface is down.
• UP—The link layer of the interface is up.
Description Interface description.
The Maximum Transmit Unit is 1500 MTU.
Hold timer is 10(sec) Value of the T391 parameter at the DTE side.
Internet Address is 12.12.12.2/16 IP address and mask.
link-protocol is FR IETF Link layer protocol.
LMI DLCI is 0, LMI type is Q.933a, frame relay DTE
DLCI number used by LMI, LMI type, port type and
operating mode.
LMI status enquiry sent 435, LMI status received 435
Number of sent LMI Status-Enquiry messages and
number of the received LMI Status messages.
LMI status timeout 0, LMI message discarded 0
Number of LMI Status messages that timed out and the
number of dropped LMI messages.
Physical is MFR Physical interface is MFR.
Output queue: (Urgent queue:
Size/Length/Discards)
Output queue: (Protocol queue:
Size/Length/Discards)
Output queue: (FIFO queuing:
Size/Length/Discards)
Statistics on the packets of the following interface output
queues:
• Urgent queue.
• Protocol queue.
• FIFO queue.
Last clearing of counters
Last time when the interface statistics were cleared.
Never indicates that the interface statistics have never
been cleared.
Last 300 seconds input rate
Input rate of the interface within the last 5 minutes. The
input rate is represented in Bps, bps, and pps.