R2511-HP MSR Router Series Layer 2 - WAN Command Reference(V5)
159
DCC configuration commands
Configure all synchronous/asynchronous serial interfaces involved in DCC configuration to operate in
asynchronous mode with the physical-mode async command.
bandwidth
Use bandwidth to set the intended bandwidth for an interface.
Use undo bandwidth to restore the default.
Syntax
bandwidth bandwidth-value
undo bandwidth
Views
Dialup interface (physical interface or dialer interface) view
Default command level
2: System level
Parameters
bandwidth-value: Specifies the intended bandwidth for the interface, in the range of 1 to 4294967295
kbps.
Usage guidelines
You can get the intended bandwidth of an interface by querying the ifspeed value of the MIB node with
third-party software.
The intended bandwidth is used for bandwidth monitoring of the network management. It does not affect
the actual bandwidth of the interface.
Examples
# Set the intended bandwidth to 1000 kbps for interface Dialer 1.
<Sysname> system-view
[Sysname] interface dialer 1
[Sysname-Dialer1] bandwidth 1000
dialer bundle
Use dialer bundle to associate a dialer bundle with a dialer interface in RS-DCC.
Use undo dialer bundle to remove the association.
Syntax
dialer bundle number
undo dialer bundle
Default
Dialer interfaces are not associated with any dialer bundle in RS-DCC.