R2511-HP MSR Router Series Layer 2 - WAN Command Reference(V5)
175
dialer timer warmup
Use dialer timer warmup to configure the warm-up timer for dynamic route backup.
Use undo dialer timer warmup to restore the default.
Syntax
dialer timer warmup seconds
undo dialer timer warmup
Default
The warm-up timer is 30 seconds, or dynamic route backup takes effect 30 seconds after a system reboot.
Views
System view
Default command level
2: System level
Parameters
seconds: Sets the warm-up timer for dynamic route backup, in the range of 0 to 66635 seconds.
Usage guidelines
The warm-up timer for dynamic route backup starts upon system reboot, and before it expires, the
dynamic route backup function is disabled and the system cannot dial a secondary link even if the
corresponding primary link is down. If the primary link has not gone up when the timer expires, the
system dials the secondary link. After the primary link goes up, the system switches over to it.
Examples
# Set the warm-up timer to 20 seconds for dynamic route backup.
<Sysname> system-view
[Sysname] dialer timer warmup 20
dialer user
Use dialer user to add a remote username for authenticating incoming calls.
Use undo dialer user to remove the remote username.
Syntax
dialer user username
undo dialer user [ username ]
Default
No remote username is set.
Views
Dialer interface view
Default command level
2: System level