R2511-HP MSR Router Series Layer 2 - WAN Command Reference(V5)

265
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer poll 2000
llc2 timer reject
Use llc2 timer reject to configure the LLC2 REJ status timer, the amount of time the router waits for the
expected frame after it receives an unexpected frame and sends a reject frame.
Use undo llc2 timer reject to restore the default.
Syntax
llc2 timer reject mseconds
undo llc2 timer reject
Default
The LLC2 REJ status timer is 500 milliseconds.
Views
Ethernet interface view
Default command level
2: System level
Parameters
mseconds: LLC2 REJ status timer in milliseconds. The range is 1 to 60000.
Examples
# Set the LLC2 REJ status timer to 2000 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer reject 2000
reset dlsw circuits
Use reset dlsw circuits to clear DLSw virtual circuit information.
Syntax
reset dlsw circuits [ circuit-id ]
Views
User view
Default command level
2: System level
Parameters
circuit-id: DLSw virtual circuit ID in the range of 0 to 0xFFFFFFFF.
Usage guidelines
This command without circuit-id clears the information of all DLSw virtual circuits. Otherwise, this