84
timer-name Timer-name
Time-out value range
(in seconds)
Default (in seconds)
t308 T308 2 to 10 4
t309 T309 10 to 180 90
t310 T310 10 to 180 40
t313 T313 2 to 10 4
t316 T316 20 to 180 120
t322 T322 2 to 10 4
Usage guidelines
Table 14 lists the defaults of the DSS1 ISDN protocol L3 timers. For the defaults of the L3 timers in any
other ISDN protocol, perform the display isdn parameters command.
Examples
# Set the time-out value of the L3 timer T301 on the interface BRI 2/0 to 160 seconds.
<Sysname> system-view
[Sysname] interface bri 2/0
[Sysname-Bri2/0] isdn l3-timer t301 160
isdn link-mode
Use isdn link-mode p2p to configure a BRI interface to operate in point-to-point mode.
Use undo isdn link-mode to restore the default BRI interface operating mode.
Syntax
isdn link-mode p2p
undo isdn link-mode
Default
A BRI interface operates in point-to-multipoint mode, in which a BRI interface operating on the network
side can have multiple end devices attached to it.
Views
ISDN BRI interface view
Default command level
2: System level
Examples
# Configure interface BRI2/0 to operate in point-to-point mode.
<Sysname> system-view
[Sysname] interface bri 2/0
[Sysname-Bri2/0] isdn link-mode p2p
isdn number-property
Use isdn number-property to set the number type and code scheme for the calling or called numbers in
incoming or outgoing ISDN calls.