R2511-HP MSR Router Series Layer 3 - IP Services Configuration Guide(V5)
209
FF02::2
FF02::1
MTU is 1480 bytes
ND reachable time is 30000 milliseconds
ND retransmit interval is 1000 milliseconds
Hosts use stateless autoconfig for addresses
IPv6 Packet statistics:
InReceives: 55
...
# Ping the IPv6 address of Ethernet 1/1 at the peer end from Router A.
[RouterA] ping ipv6 3003::1
PING 3003::1 : 56 data bytes, press CTRL_C to break
Reply from 3003::1
bytes=56 Sequence=1 hop limit=64 time = 1 ms
Reply from 3003::1
bytes=56 Sequence=2 hop limit=64 time = 1 ms
Reply from 3003::1
bytes=56 Sequence=3 hop limit=64 time = 1 ms
Reply from 3003::1
bytes=56 Sequence=4 hop limit=64 time = 1 ms
Reply from 3003::1
bytes=56 Sequence=5 hop limit=64 time = 1 ms
--- 3003::1 ping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 1/1/1 ms
Configuring an automatic IPv4-compatible IPv6
tunnel
Configuration prerequisites
Configure an IP addresses for the interface (such as a VLAN interface, Ethernet interface, or a loopback
interface) to be used as the source interface of the tunnel interface.
Configuration guidelines
Follow these guidelines when you configure an automatic IPv4-compatible IPv6 tunnel:
• No destination address needs to be configured for an automatic IPv4-compatible IPv6 tunnel.
Because the destination address of the tunnel is embedded in the destination IPv4-compatible IPv6
address of packets.
• The tunnel interfaces using the same encapsulation protocol cannot use the same source IP address.