R2511-HP MSR Router Series MPLS Configuration Guide(V5)

400
LocalLspID : 1
Tunnel-Interface : Tunnel4
Fec : 4.4.4.4/32
Nexthop : 3.1.1.2
In-Label : 1024
Out-Label : 1024
In-Interface : Ethernet1/1
Out-Interface : Ethernet1/2
LspIndex : 4097
Tunnel ID : 0x22001
LsrType : Transit
Bypass In Use : In Use
BypassTunnel : Tunnel Index[Tunnel5], InnerLabel[1024]
Mpls-Mtu : 1500
No : 2
IngressLsrID : 2.2.2.2
LocalLspID : 1
Tunnel-Interface : Tunnel5
Fec : 3.3.3.3/32
Nexthop : 3.2.1.2
In-Label : NULL
Out-Label : 1024
In-Interface : ----------
Out-Interface : POS5/0
LspIndex : 4098
Tunnel ID : 0x22002
LsrType : Ingress
Bypass In Use : Not Exists
BypassTunnel : Tunnel Index[---]
Mpls-Mtu : 1500
# Set the FRR polling timer to five seconds on PLR.
[RouterB] mpls
[RouterB-mpls] mpls te timer fast-reroute 5
[RouterB-mpls] quit
# Bring the protected outgoing interface up on PLR.
[RouterB] interface ethernet 1/2
[RouterB-Ethernet1/2] undo shutdown
%Sep 7 09:01:31 2004 RouterB IFNET/5/UPDOWN:Line protocol on the interface
Ethernet1/2 turns into UP state
# Execute the display interface tunnel 4 command on Router A to display the state of the primary
LSP. The output shows that the tunnel interface is up.
About five seconds later, execute the display mpls lsp verbose command on Router B. The output
shows that Tunnel 5 is still bound with interface Ethernet 1/2 and is unused.
7. Create a static route to direct traffic to the MPLS TE tunnel:
[RouterA] ip route-static 4.1.1.2 24 tunnel 4 preference 1