Examples
# Display power information for GigabitEthernet 1/1.
<Sysname> display poe interface power gigabitethernet 1/1
Interface CurPower PeakPower MaxPower PD Description
(W) (W) (W)
GE1/1 15.0 15.3 15.4 Acess Point on Room 509 for Peter
# Display power information for all PoE interfaces.
<Sysname> display poe interface power
Interface CurPower PeakPower MaxPower PD Description
(W) (W) (W)
GE1/25 4.4 4.5 4.6 IP Phone on Room 309 for Peter Smith
GE1/26 4.4 4.5 15.4 IP Phone on Room 409 for Peter Pan
GE1/27 15.0 15.3 15.4 Acess Point on Room 509 for Peter
GE1/28 0.0 0.0 0.0 IP Phone on Room 609 for Peter John....
GE1/29 0.0 0.0 0.0 IP Phone on Room 709 for Jack
GE1/30 0.0 0.0 0.0 IP Phone on Room 809 for Alien
--- 3 port(s) on, 23.8(W) consumed, 776.2(W) Remaining ---
Table 51 Command output
Field Description
Interface Shortened form of a PoE interface.
CurPower Current power of a PoE interface.
PeakPower Peak power of a PoE interface.
MaxPower Maximum power of a PoE interface.
PD Description
Description of the PD connected with a PoE interface.
When the description contains more than 34
characters, the first 30 characters followed by four
dots are displayed.
port(s) on Number of PoE interfaces that are supplying power.
consumed Power consumed by all PoE interfaces.
Remaining Total remaining power of the system.
display poe power-usage
Use display poe power-usage to display power usage statistics for PoE power supplies and PSEs.
Syntax
display poe power-usage [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
1: Monitor level