R2511-HP MSR Router Series Network Management and Monitoring Configuration Guide(V5)

80
Configuring the CPE username and password
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter CWMP view.
cwmp N/A
3. Configure the CPE username
for connection to the CPE.
cwmp cpe username username
By default, no CPE username is
configured for connection to the
CPE.
4. Configure the CPE password
for connection to the CPE.
cwmp cpe password [ cipher |
simple ] password
Optional.
You can specify a username
without a password for
authentication, but make sure the
ACS has the same authentication
setting as the CPE.
By default, no CPE password is
configured for connection to the
CPE.
Configuring the CWMP connection interface
The CWMP connection interface is the interface that the CPE uses to communicate with the ACS. The CPE
sends the IP address of this interface in the Inform messages and the ACS replies to this IP address for
setting up a CWMP connection.
If the interface that connects the CPE to the ACS is the only Layer 3 interface that has an IP address on
the device, you do not need to specify the CWMP connection interface. If multiple Layer 3 interfaces are
configured, specify the CWMP connection interface to make sure the IP address of the interface that
connects to the ACS is sent to the ACS for setting up CWMP connection.
To configure a CWMP connection interface:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter CWMP view.
cwmp N/A
3. Set the interface that
connects the CPE to the
ACS.
cwmp cpe connect interface
interface-type interface-number
The default CWMP connection
interface is the interface that is
assigned an IP address first among all
interfaces on the CPE.
Sending Inform messages
Inform messages need to be sent during the connection establishment between a CPE and an ACS. You
can configure the Inform message sending parameter to trigger the CPE to initiate a connection to the
ACS.
To configure the CPE to periodically send Inform messages: