R2511-HP MSR Router Series Network Management and Monitoring Configuration Guide(V5)

81
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter CWMP view.
cwmp N/A
3. Enable the periodic sending
of Inform messages.
cwmp cpe inform interval enable By default, this function is disabled.
4. Configure the interval
between sending the Inform
messages.
cwmp cpe inform interval seconds
Optional.
By default, the CPE sends an Inform
message every 600 seconds.
To configure the CPE to send an Inform message at a specific time:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter CWMP view.
cwmp N/A
3. Configure the CPE to send an
Inform message at a specific
time.
cwmp cpe inform time time
By default, no time is set. The CPE
is not configured to send an Inform
message at a specific time.
Configuring the maximum number of attempts made to retry a
connection
If a CPE fails to establish a connection to an ACS or the connection is interrupted during the session (the
CPE does not receive a message indicating the normal close of the session), the CPE can automatically
reinitiate a connection to the ACS.
To configure the maximum number of attempts that the CPE can make to retry a connection:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter CWMP view.
cwmp N/A
3. Configure the maximum
number of attempts that the
CPE can make to retry a
connection.
cwmp cpe connect retry times
Optional.
By default, the CPE regularly sends
connection requests to the ACS
until a connection is set up.
Configuring the close-wait timer of the CPE
The close-wait timer is used mainly in the following cases:
During the establishment of a connection, if the CPE sends a connection request to the ACS, but the
CPE does not receive a response within the configured close-wait timeout, the CPE considers the
connection as having failed.
After a connection is established, if there is no packet interaction between the CPE and the ACS
within the configured close-wait timeout, the CPE considers the connection to be invalid and
disconnects the connection.