OAP module configuration commands
The following matrix shows the feature and router compatibility:
Hardware OAP module
OAA
MSR900 No. No.
MSR93X No. No.
MSR20-1X No. Yes.
MSR20 No. No.
MSR30 Yes. Yes.
MSR50 Yes. Yes.
MSR1000 No. No.
oap connect
Use oap connect to switch to the CLI of the OAP module from the device.
Syntax
oap connect slot slot-number [ system system-name ]
Views
User view
Default command level
1: Monitor level
Parameters
slot slot-number: Specifies the number of the slot where an OAP module resides.
system system-name: Specifies the OAP name or the number of the slot where the OAP module resides.
Support for this option depends on the device model.
Usage guidelines
To return to the device's CLI, press Ctrl+K.
Examples
# Switch to the CLI of the OAP module in slot 3 from the device.
<Sysname> oap connect slot 3
Press CTRL+K to quit.
Connected to OAP!
# Log in to the i-ware system in slot 3 from the device.
<Sysname> oap connect slot 3 system i-ware
Press CTRL+K to quit.
Connected to i-ware!