R2511-HP MSR Router Series Terminal Access Command Reference(V5)

13
Access devices send flow control character strings received from terminals to the FEP. If the FEP receives
a packet that contains flow control characters 0x13, which enables flow control, and 0x11, wh i c h
disables flow control, the FEP enables flow control but does not disable it. As a result, the FEP stops
sending data to the corresponding terminal, and the display pauses until you disable flow control by
pressing the shortcut keys. To prevent this problem, configure the device to filter flow control characters
out of the data received from terminals and to perform flow control by itself.
Examples
# Enable filtering of flow control characters 0x11 and 0x13 carried in the received data flows.
<Sysname> system-view
[Sysname] rta template abc
[Sysname-rta-template-abc] filter flow-control character
idle-timeout
Use idle-timeout to set the TCP connection idle timeout time for terminal access.
Use undo idle-timeout to restore the default.
Syntax
idle-timeout seconds
undo idle-timeout
Default
The TCP connection never times out.
Views
Terminal template view
Default command level
2: System level
Parameters
seconds: Connection idle timeout time, in seconds, ranging 10 to 3600.
Usage guidelines
When the idle timeout time is configured, if no data is transmitted over the terminal access connection for
the specified period of time, the connection is automatically torn down.
Examples
# Set the terminal access idle timeout time to 1000 seconds.
<Sysname> system-view
[Sysname] rta template abc
[Sysname-rta-template-abc] idle-timeout 1000
menu hotkey
Use menu hotkey to configure the menu hotkey.
Use undo menu hotkey to cancel the menu hotkey.
Syntax
menu hotkey ascii-code&<1-3>