R2511-HP MSR Router Series Terminal Access Configuration Guide(V5)

20
Ste
p
Command Remarks
3. Create a terminal template
and enter terminal template
view.
rta template template-name N/A
4. Configure a Telnet VTY.
vty vty-number telnet remote
ip-address [ port-number ] [ source
source-ip ]
After this configuration, the
template can be configured with
Telnet VTYs, but not RTC client
VTYs or RTC server VTYs.
5. Exit terminal template view.
quit N/A
6. Enter interface view.
interface interface-type
interface-number
The interface type must be
supported by terminal access.
7. Configure the asynchronous
serial interface to operate in
flow mode.
async mode flow
By default, an asynchronous serial
interface operates in the protocol
mode and an AUX interface the
flow mode.
For more information about the
async mode flow command, see
the async mode command in
Interface Command Reference.
8. Apply the template to an
interface.
rta terminal template-name
terminal-number [ backup ]
After you apply the template to the
interface, you must set the flow
control mode of the user interface
corresponding to the interface to
software flow control. To view
associations between interfaces
and user interfaces, use the display
user-interface command.
9. Exit interface view.
quit N/A
10. Enter TTY user interface view.
user-interface { first-num1
[ last-num1 ] | tty first-num2
[ last-num2 ] }
For more information about the
user-interface command, see the
user-interface command in
Fundamentals Command
Reference.
11. Enable software flow control
of data on the current user
interface.
flow-control software
By default, the flow control mode is
none. That is, no flow control is
implemented.
For more information about the
flow-control software command,
see the flow-control command in
Fundamentals Command
Reference.
Advanced Telnet initiator configuration
When you configure advanced Telnet initiator settings, follow these guidelines:
If both the global source IP address and the source IP address of a VTY are configured, the source
IP address of the VTY is used.
Configure TCP parameters before establishing a TCP connection. If you configure parameters after
a TCP connection is established, the TCP connection must be re-established for the parameters to
take effect. You can press the reset hotkey on the terminal to re-establish the TCP connection.