R2511-HP MSR Router Series Terminal Access Configuration Guide(V5)
31
Ste
p
Command
Remarks
7. Configure the asynchronous
serial interface to operate in
flow mode.
async mode flow
By default, an asynchronous serial
interface operates in the protocol
mode and an AUX interface the flow
mode.
For more information about the async
mode flow command, see the async
mode command in Interface
Command Reference.
8. Apply the template to the
interface.
rta terminal template-name
terminal-number [ backup ]
After you apply the template to the
interface, you must set the flow control
mode of the user interface
corresponding to the interface to
software flow control. To view
associations between interfaces and
user interfaces, use the display
user-interface command.
9. Exit interface view.
quit N/A
10. Enter TTY user interface view.
user-interface { first-num1
[ last-num1 ] | tty first-num2
[ last-num2 ] }
For more information about the
user-interface command, see the
user-interface command in
Fundamentals Command Reference.
11. Enable software flow control
of data on the current user
interface.
flow-control software
By default, the flow control mode is
none. That is, no flow control is
implemented.
For more information about the
flow-control software command, see
the flow-control command in
Fundamentals Command Reference.
Advanced SSH initiator configuration
When you configure advanced SSH initiator settings, follow these guidelines:
• If both the global source IP address and the source IP address of a VTY are configured, the source
IP address of the VTY is used.
• Configure TCP parameters before TCP connections are established. If you configure the parameters
after a TCP connection is established, the TCP connection must be re-established for the parameters
to take effect. You can press the reset hotkey on the terminal to re-establish the TCP connection.
• The receive buffer size must be configured before the terminal template is applied. If you configure
the receive buffer size after a terminal template is applied, you must remove the application of the
terminal template and apply the terminal template again for the receive buffer size to take effect.
• The ASCII value of the hotkey must be different from the ASCII value of any other hotkey configured
on the device. Otherwise, hotkey conflicts will occur. For example, the hotkey value cannot be 17 or
19 because these two values are used for flow control. In addition, using the hotkey may not get a
fast response when the terminal display is busy.
• Make sure that the terminal type configured is the actual type of the terminal. Otherwise, the screen
becomes illegible when it is redrawn or the VTY is changed.
• If you modify the screen saving configuration after a terminal connection is already established, you
must use the update changed-config command to apply the latest configuration.










