R2511-HP MSR Router Series Terminal Access Configuration Guide(V5)
37
Ste
p
Command Remarks
12. Enable software flow control
of data on the current user
interface.
flow-control software
By default, the flow control mode is
none. That is, no flow control is
implemented.
For more information about the
flow-control software command,
see the flow-control command in
Fundamentals Command
Reference.
Advanced RTC initiator configuration
When you configure advanced RTC initiator settings, follow these guidelines:
• To implement terminal access authentication, you must configure terminal access authentication on
both the RTC server and the RTC client, and the authentication passwords must be identical for the
authentication to succeed.
• The bind vpn-instance command is used when the RTC client also acts as an MPLS PE router at the
same time. When you apply a terminal template configured with the bind vpn-instance command
to an asynchronous serial interface, the terminal connected to the asynchronous serial interface is
bound with the VPN instance. The RTC client can receive terminal access packets from multiple
VPNs and initiate connection requests through multiple asynchronous serial interfaces.
• If both the global source IP address and the source IP address for a VTY are configured, the source
IP address for the VTY is used.
• Configure TCP parameters before a TCP connection is established. If you configure the parameters
after a TCP connection is established, the TCP connection must be re-established for the parameters
to take effect. You can press the reset hotkey on the terminal to re-establish the TCP connection.
• Configure the receive buffer size before applying the terminal template. If you configure the receive
buffer size after a terminal template is applied, remove the application of the terminal template and
re-apply the terminal template for the receive buffer size to take effect.
• The ASCII value of the hotkey must be different from the ASCII value of any other hotkey configured
on the device. Otherwise, hotkey conflicts will occur. For example, the hotkey value cannot be 17 or
19 because these two values are used for flow control. In addition, using the hotkey may not get a
fast response when the terminal display is busy.
To configure advanced RTC initiator (RTC Client) settings:
Ste
p
Command Remarks
1. Enter system view.
system-view
N/A
2. Configure the global
source IP address for TCP
connections.
rta source-ip ip-address
Optional.
Not configured by default.
3. Configure the RTC terminal
access version as v3.
rta rtc version { v3 | v5 }
Optional.
v5 by default.
4. Enter terminal template
view.
rta template template-name
N/A
5. Configure the automatic
link teardown time.
auto-close time
Optional.
0 seconds by default. That is, no
automatic link teardown is performed.