R2511-HP MSR Router Series Terminal Access Configuration Guide(V5)
40
Ste
p
Command
Remarks
7. Enter interface view.
interface
interface-type
interface-number
The interface type must be
supported by terminal access.
Synchronous and asynchronous
interfaces are supported.
8. Configure the asynchronous
serial interface to operate in
flow mode.
async mode flow
Use either command.
By default, an asynchronous serial
interface operates in the protocol
mode, an AUX interface operates
in the flow mode, and a serial
interface operates in the PPP
protocol mode.
For more information about the
async mode flow command, see
the async mode command in
Interface Command Reference.
9. Configure the protocol type of
the synchronous serial
interface as HDLC.
link-protocol hdlc
10. Apply the template to an
interface.
rta terminal template-name
terminal-number [ backup ]
After you apply the template to the
interface, you must set the flow
control mode of the user interface
corresponding to the interface to
software flow control. To view
associations between interfaces
and user interfaces, use the display
user-interface command.
11. Exit interface view.
quit N/A
12. Enter TTY user interface view.
user-interface { first-num1
[ last-num1 ] | tty first-num2
[ last-num2 ] }
For more information about the
user-interface command, see the
user-interface command in
Fundamentals Command
Reference.
13. Enable software flow control
of the data on the current user
interface.
flow-control software
By default, the flow control mode is
none. That is, no flow control is
implemented.
For more information about the
flow-control software command,
see the flow-control command in
Fundamentals Command
Reference.
Advanced TCP_11_Server configuration
When you configure advanced TCP_11_Server settings, follow these guidelines:
• The port number specified for the VTY application on the RTC client must be the same as the
listening port number specified on the RTC server.
• The vty-number argument of the command vty rtc-server remote configured on the RTC server must
be the same as the terminal-number argument of the command rta terminal configured on the RTC
client. Otherwise, no TCP connection can be established.
• Each terminal of the RTC server corresponds to a different RTC client.
• If not configured with the bind vpn-instance command, the RTC server can accept connection
requests from any VPNs.