R2511-HP MSR Router Series Voice Command Reference(V5)
98
[Sysname-subscriber-line5/0] slic-gain 1
subscriber-line
Use subscriber-line to enter the specified voice subscriber line view.
Syntax
subscriber-line line-number
Views
System view
Default command level
2: System level
Parameters
line-number: Voice subscriber line number.
Examples
# Enter the view of the voice subscriber line 1/0 in system view.
<Sysname> system-view
[Sysname] subscriber-line 1/0
[Sysname-subscriber-line1/0]
timer dial-interval
Use timer dial-interval to configure the maximum interval for dialing the next digit.
Use undo timer dial-interval to restore the default setting.
Syntax
timer dial-interval seconds
undo timer dial-interval
Default
The maximum interval for dialing the next digit is 10 seconds.
Views
FXS voice subscriber line view, FXO voice subscriber line view, E&M voice subscriber line view
Default command level
2: System level
Parameters
seconds: Maximum interval in seconds for dialing the next digit, in the range of 1 to 300.
Usage guidelines
This timer will restart each time the subscriber dials a digit and will operate in this way until all the digits
of the number are dialed. If the timer expires before the dialing is completed, the subscriber will be
prompted to hook up and the call will be terminated.
Examples
# Set the maximum duration waiting for the next digit on voice line 1/0 to 5 seconds.