R2511-HP MSR Router Series Voice Command Reference(V5)
116
Field Description
Type
Type of the voice subscriber line or signaling used by the voice subscriber line:
• PAGE—PAGE subscriber line.
• FXS-LS—FXS subscriber line that uses loop-start signaling.
• FXO-LS—FXO subscriber line that uses loop-start signaling.
• FXS-GS—FXS subscriber line that uses ground-start signaling.
• FXO-GS—FXO subscriber line that uses ground-start signaling.
• R2—Subscriber line that uses R2 signaling.
• ISDN—Subscriber line that uses ISDN signaling.
• E&M-DLY—Subscriber line that uses the delay start mode.
• E&M-WNK—Subscriber line that uses the wink start mode.
• E&M-IMD—Subscriber line that uses the immediate start mode.
• Unknown.
Phy-status
Status of the voice subscriber line:
• ADM—The subscriber line is shut down with the shutdown command.
• DOWN—The subscriber line is administratively up but physically down
(possibly because no physical link is present or the link has failed).
• UP(S)—The subscriber line is up at the link layer, but its link is an on-demand
link or not present at all. This attribute is typical of BSV interfaces.
• UP—The subscriber line is up.
Call Status
Call status of the voice subscriber line:
• IDLE.
• SENDNUMBER.
• RECEIVENUMBER.
• CALLIN—The subscriber line is in callout state.
• CALLOUT—The subscriber line is in callin state.
• SEIZE.
• SEIZEACK.
• RING.
• RINGBACK.
• BUSYTONE.
• TALKING.
• RELEASING.
• BINDINSTALLING—The FXO subscriber line is being installed.
• BINDFXOOFFHOOK—The FXO subscriber line is bound and in forced off-hook
state.
• BINDFXOONHOOK—The FXO subscriber line is bound and in forced on-hook
state.
• UNKNOWN.
• N/A—There is no call status for the subscriber line.
Private-line
Called number for the PLAR function:
• N/A—The subscriber line does not support the PLAR function.
• Not Set—The subscriber line is not configured with the PLAR function.