R2511-HP MSR Router Series Voice Command Reference(V5)

117
dl-bits
NOTE:
This command applies to R2 signaling only.
Use dl-bits to configure the ABCD bit pattern for R2 signals.
Use undo dl-bits to restore the defaults.
Syntax
dl-bits { answer | blocking | clear-back | clear-forward | idle | seize | seizure-ack | release-guard }
{ received | transmit } ABCD
undo dl-bits { answer | blocking | clear-back | clear-forward | idle | seize | seizure-ack |
release-guard } { received | transmit }
Views
R2 CAS view
Default command level
2: System level
Parameters
answer: Answer signal of R2 line signaling.
blocking: Blocking signal of R2 line signaling.
clear-back: Clear-back signal of R2 line signaling.
clear-forward: Clear-forward signal of R2 line signaling.
idle: Idle signal of R2 line signaling.
seize: Seizure signal of R2 line signaling.
seizure-ack: Seizure acknowledgement signal of R2 line signaling.
release-guard: Release guard signal of R2 line signaling.
received: Indicates that the signaling setting applies to received R2 line signals.
transmit: Indicates that the signaling setting applies to transmitted R2 line signals.
ABCD: ABCD bit pattern of R2 line signals, in the range of 0000 to 1111.
Table 29 Default values of signals in R2 digital line signaling
Signal Default rx-bits
ABCD
Default tx-bits
ABCD
Answer 0101 0101
Blocking 1101 1101
Clear-back 1101 1101
Clear-forward 1001 1001
Idle 1001 1001
Seize 0001 0001
Seizure-ack 1101 1101