R2511-HP MSR Router Series Voice Command Reference(V5)
121
force-metering enable
NOTE:
This command applies to R2 signaling only.
Use force-metering enable to enable R2 metering signal processing.
Use undo force-metering enable to disable R2 metering signal processing.
Syntax
force-metering enable
undo force-metering enable
Default
R2 metering signal processing is disabled.
Views
R2 CAS view
Default command level
2: System level
Usage guidelines
When the terminating side supports metering signals, the system can send a forced release signal
instead of a clear-back signal to release the line. This is to avoid collision between the clear-back signal
sent by the called party and the metering signal.
Examples
# Enable R2 metering signal processing.
<Sysname> system-view
[Sysname] controller e1 1/0
[Sysname-e1 1/0] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-e1 1/0] cas 0
[Sysname-cas1/0:0] force-metering enable
group-b enable
NOTE:
This command applies to R2 signaling only.
Use group-b enable to enable R2 signaling to use Group B signals to complete registers exchange.
Use undo group-b enable to disable R2 signaling from using Group B signals to complete registers
exchange.
Syntax
group-b enable
undo group-b enable
Default
Group B signals are used to complete registers exchange.