R2511-HP MSR Router Series Voice Command Reference(V5)

125
calling calling-number: Specifies a calling number, a string of up to 31 characters that can only contain
0 through 9. Traffic matching the specified calling number is mirrored.
bdsp: Mirrors the PCM data of the back-end DSP of the specified time slot.
fdsp: Mirrors the PCM data of front-end DSP of the specified time slot.
command: Mirrors voice command data.
channel-number: Specifies a time slot in the range of 0 to 29. The data on the specified time slot will be
mirrored.
to: Specifies a destination interface or destination IP address for mirrored traffic.
local-interface interface-type interface-number: Specifies a destination interface, which must be a Layer-2
or Layer-3 Ethernet port.
mac: Specifies a destination MAC address for mirrored traffic, in the format H-H-H. You can remove the
leading 0s in Hs from the MAC address. For example, f-e2-1 represents 000f-00e2-0001.
remote-ip ip-address: Specifies a destination IP address for mirrored traffic.
port port: Specifies a destination port for mirrored traffic. The default port is 60000.
Usage guidelines
The router supports only one PCM data mirror entry.
This command is only applicable to the digital voice subscriber lines generated on VE1, VT1, and BSV
interfaces.
Examples
# Mirror the PCM data for the calling number 55501234 on subscriber-line 1/0:0 generated on the VE1
interface to the interface Ethernet 1/1.
<Sysname> system-view
[Sysname] subscriber-line 1/0:0
[Sysname-subscriber-line1/0:0] mirror number 1 pcm calling 55501234 to local-interface
ethernet 1/1
mode
NOTE:
This command applies to R2 signaling only.
Use mode to configure a national R2 signaling variant.
Use undo mode to restore the default.
Syntax
mode zone-name [ default-standard ]
undo mode
Default
ITU-T R2 signaling applies.
Views
R2 CAS view