R2511-HP MSR Router Series Voice Command Reference(V5)

142
Default command level
2: System level
Parameters
seconds: Interval (in seconds) at which the interface sends keepalive packets, in the range 0 to 32767.
Examples
# Set the keepalive interval to 100 seconds for interface BSV BRI 2/0.
<Sysname> system-view
[Sysname] interface bri 2/0
[Sysname-Bri2/0] timer hold 100
timer register-pulse persistence
NOTE:
This command applies to R2 signaling only.
Use timer register-pulse persistence to configure the duration of R2 register pulse signals such as A-3,
A-4, and A-6.
Use undo timer register-pulse persistence to restore the default.
Syntax
timer register-pulse persistence time
undo timer register-pulse persistence
Default
The duration is 150 milliseconds.
Views
R2 CAS view
Default command level
2: System level
Parameters
persistence time: Duration in milliseconds of R2 register pulse signals, in the range of 50 to 3000.
Usage guidelines
When the terminating side sends a backward register pulse signal, A-3 for example, the signal must
persist for a specified time period. When the originating side receives the signal, it sends back a Group
II forward signal. When the originating side recognizes the pulse signal, A4, A6, or A15, it stops
sending any forward signal, and terminates the register signal exchange.
Examples
# Set the duration of R2 register pulse signals to 300 milliseconds.
<Sysname> system-view
[Sysname] controller e1 1/0
[Sysname-e1 1/0] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-e1 1/0] cas 0
[Sysname-cas1/0:0] timer register-pulse persistence 300