R2511-HP MSR Router Series Voice Command Reference(V5)
143
Related commands
timer register-complete group-b
timer register-complete group-b
NOTE:
This command applies to R2 signaling only.
Use timer register-complete group-b to configure the timeout value of R2 group B signals. After the
terminating side switch to Group B, it should send Group B signals within this time period.
Use undo timer register-complete group-b to restore the default timeout value of R2 group B signals.
Syntax
timer register-complete group-b time
undo timer register-complete group-b
Default
The maximum time is 30,000 milliseconds.
Views
R2 CAS view
Default command level
2: System level
Parameters
group-b time: Maximum time in milliseconds that the originating side waits for R2 Group B signals, in the
range of 100 to 90000.
Examples
# Configure the maximum Group B signal exchange time to 10,000 milliseconds.
<Sysname> system-view
[Sysname] controller e1 1/0
[Sysname-e1 1/0] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-e1 1/0] cas 0
[Sysname-cas1/0:0] timer register-complete group-b 10000
Related commands
timer dl
timer ring
NOTE:
This command applies to R2 signaling only.
Use timer ring to configure the duration of playing a signal tone when R2 signaling is adopted.
Use undo timer ring to restore the default duration of playing a signal tone.
Syntax
timer ring { ringback | ringbusy } time