R2511-HP MSR Router Series Voice Command Reference(V5)

162
Default command level
2: System level
Parameters
priority-order: Priority of a voice entity, in the range of 0 to 10. The smaller the value, the higher the
priority.
Usage guidelines
If you have configured priority levels for voice entities and the selection priority rules (see the select-rule
commands), the router selects the voice entity with the highest priority to initiate a call.
Examples
# Set the priority level of voice entity 10 to 5.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] dial-program
[Sysname-voice-dial] entity 10 pots
[Sysname-voice-dial-entity10] priority 5
Related commands
select-rule
private-line
Use private-line to configure the PLAR function.
Use undo private-line to disable the private line auto ring-down function.
Syntax
private-line string
undo private-line
Default
The private line auto ring-down function is disabled.
Views
FXS voice subscriber line view, FXO voice subscriber line view, E&M voice subscriber line view, BSV voice
subscriber line view
Default command level
2: System level
Parameters
string: E.164 telephone number of the terminating end, a string of 31 digits/characters, which can
include 0 through 9, asterisk (*), and pound sign (#).
Usage guidelines
This command is applicable to FXO, FXS, analog E&M interface and digital E1 or T1 voice interface.
Examples
# Configure the private line auto ring-down function on voice subscriber line 1/0 so that 5559262 is
automatically dialed out when the subscriber picks up the phone.
<Sysname> system-view