Use undo em-signal to restore the default start mode.
Syntax
em-signal { delay | immediate | wink }
undo em-signal
Default
The immediate start mode is selected for the analog E&M subscriber line.
Views
Analog E&M voice subscriber line view
Default command level
2: System level
Parameters
delay: When using the delay start mode, the calling end occupies the trunk line, and the called end, such
as PBX, will also enter the hook-off state to respond the caller till it is ready for receiving the called
number.
immediate: Immediate start mode. The caller end hooks off to seize the line through line E and sends the
called number. The immediate start mode is applicable when the equipment at the remote end is able to
detect the dial signal immediately after identifying the off-hook signal.
wink: Wink start mode. The caller end hooks off to seize the line through line E, and it has to wait for a
wink signal from the remote end before sending out the called number.
Examples
# Configure delay mode for E&M voice subscriber line 1/0.
<Sysname> system-view
[Sysname] subscriber-line 5/0
[Sysname-subscriber-line5/0] em-signal delay
em-passthrough
Use em-passthrough to enable E&M analog control signals pass-through.
Use undo em-passthrough to disable E&M analog control signals pass-through.
Syntax
em-passthrough
undo em-passthrough
Default
E&M analog control signals pass-through is disabled.
Views
Analog E&M voice subscriber line view
Default command level
2: System level
Examples
# Enable E&M analog control signals pass-through for E&M voice subscriber line 6/0.