[RouterB-voice-dial] entity1001 pots
[RouterB-voice-dial-entity1001] match-template 010....
[RouterB-voice-dial-entity1001] line 1/1
[RouterB-voice-dial-entity1001] send-number all
[RouterB-voice-dial-entity1001] quit
# Configure rules in the match order for voice entity selection.
[RouterB-voice-dial] select-rule rule-order 1 4
3. Configure Router C:
# Configure an Ethernet address.
<RouterC> system-view
[RouterC] interface ethernet 2/1
[RouterC-Ethernet2/1] ip address 1.1.1.3 24
[RouterC-Ethernet2/1] quit
# Configure POTS entities.
[RouterC] voice-setup
[RouterC-voice] dial-program
[RouterC-voice-dial] entity 1000 pots
[RouterC-voice-dial-entity1000] match-template 010....
[RouterC-voice-dial-entity1000] line 1/0
[RouterC-voice-dial-entity1000] send-number all
[RouterC-voice-dial-entity1000] quit
[RouterC-voice-dial] entity1001 pots
[RouterC-voice-dial-entity1001] match-template 010....
[RouterC-voice-dial-entity1001] line 1/1
[RouterC-voice-dial-entity1001] send-number all
[RouterC-voice-dial-entity1001] quit
# Configure rules in the match order for voice entity selection
[RouterC-voice-dial] select-rule rule-order 1 4
Configuring the maximum-call-connection set
Network requirement
As shown in Figure 34, there are one trunking voice gateway (Router C) and two subscriber voice
gateways (Router A and Router B) in a city. To prevent the trunk lines from being totally occupied by either
subscriber voice gateway, you must restrict the number of calls originated from Router A and Router B
respectively.