R2511-HP MSR Router Series Voice Configuration Guide(V5)
239
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter voice subscriber line
view.
subscriber-line line-number N/A
3. Enable hunt group for the
voice subscriber line.
hunt-group enable Disabled by default.
NOTE:
To use the hunt group feature, you need to configure the hunt-group enable command on all involved
v
oice subscriber lines.
Configuring hunt group priority level
A priority level applies to the features of call waiting, call forwarding, and hunt group only.
By default, the priority levels for hunt group, call forwarding (excluding call forwarding unconditional),
and call waiting are 1, 2, and 3 respectively. The smaller the value is, the higher the priority level is.
When you change the priority level of a feature, make sure that different features have different priority
levels.
To configure a hunt group priority level:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter voice subscriber line
view.
subscriber-line line-number N/A
3. Configure a priority level for
hunt group.
hunt-group priority level
Optional.
1 by default.
NOTE:
The call forwarding unconditional feature is free from the restriction of priority level. If the call forwardin
g
unconditional feature is enabled, the other types of call forwardin
g
, call waitin
g
, and hunt
g
roup features
w
ill never take effect.
Configuration example
Telephone B and Telephone C have the same number, but Telephone B has a higher priority than
Telephone C (the POTS entity priority of Telephone B is configured in POTS voice view using the priority
command). Place a call from Telephone A to Telephone B and Telephone B is busy. In this case, the hunt
group service enables Telephone C to have a conversation with Telephone A.
# Enter voice subscriber line view.
<Sysname> system-view
[Sysname] subscriber-line 2/0
[Sysname-subscriber-line2/0] hunt-group enable
[Sysname-subscriber-line2/0] quit
# Enable the hunt group feature for the voice subscriber lines.
[Sysname] subscriber-line 2/1