R2511-HP MSR Router Series Voice Configuration Guide(V5)
301
After dialing the number 300 at Telephone A, the subscriber hears the voice prompts of the audio
file welcome.wav. After that, if the subscriber dials 0 at Telephone A, and Telephone B1 will ring.
Jump node configuration example
Network requirements
As shown in Figure 95, configure the IVR access number and customize Jump node functions on Router
B.
• After the subscriber originates a call through a SIP server by dialing 300 (the IVR access number of
Router B) from Telephone A, Router B plays the audio file welcome.wav. The call jumps according
to the voice prompts. Configure Router B to terminate the call when the subscriber presses #.
• If the subscriber dials a wrong number at Telephone A, Router B plays the audio file
input_error.wav.
• If the timeout value expires before the subscriber dials, Router B plays the audio file timeout.wav.
Figure 95 Network diagram
Configuration procedure
1. Configure Router A:
# Configure POTS voice entity 100.
<RouterA> system-view
[RouterA] voice-setup
[RouterA-voice] dial-program
[RouterA-voice-dial] entity 100 pots
[RouterA-voice-dial-entity100] match-template 100
[RouterA-voice-dial-entity100] line 1/0
[RouterA-voice-dial-entity100] quit
# Configure VoIP voice entity 300 to Router B.
[RouterA-voice-dial] entity 300 voip
[RouterA-voice-dial-entity300] match-template 300
[RouterA-voice-dial-entity300] address sip ip 1.1.1.2
[RouterA-voice-dial-entity300] outband sip
2. Configure Router B:
# Configure POTS voice entity 500.
<RouterB> system-view
[RouterB] voice-setup
[RouterB-voice] dial-program
[RouterB-voice-dial] entity 500 pots
[RouterB-voice-dial-entity500] match-template 500
[RouterB-voice-dial-entity500] line 1/0
[RouterB-voice-dial-entity500] quit