R2511-HP MSR Router Series Voice Configuration Guide(V5)

310
[Sysname-voice-dial-entity300] quit
[Sysname-voice-dial] quit
[Sysname-voice] ivr-system
[Sysname-voice-ivr] node 1 jump
[Sysname-voice-ivr-node1] user-input # goto-node 2
[Sysname-voice-ivr-node1] quit
[Sysname-voice-ivr] node 2 jump
[Sysname-voice-ivr-node2] user-input # goto-node 3
[Sysname-voice-ivr-node2] quit
[Sysname-voice-ivr] node 3 jump
[Sysname-voice-ivr-node3] user-input # goto-node 4
[Sysname-voice-ivr-node3] quit
[Sysname-voice-ivr] node 4 jump
[Sysname-voice-ivr-node4] user-input # goto-node 5
[Sysname-voice-ivr-node4] quit
[Sysname-voice-ivr] node 5 jump
[Sysname-voice-ivr-node5] user-input # goto-node 6
[Sysname-voice-ivr-node5] quit
[Sysname-voice-ivr] node 6 jump
[Sysname-voice-ivr-node6] user-input # goto-node 7
[Sysname-voice-ivr-node6] quit
[Sysname-voice-ivr] node 7 jump
[Sysname-voice-ivr-node7] user-input # goto-node 8
[Sysname-voice-ivr-node7] quit
[Sysname-voice-ivr] node 8 jump
[Sysname-voice-ivr-node8] user-input # goto-node 9
[Sysname-voice-ivr-node8] quit
[Sysname-voice-ivr] node 9 call
[Sysname-voice-ivr-node9] extension 1 call 300
[Sysname-voice-ivr-node9] quit
Analysis
When the IVR process jumps to node 8, it has already jumped for more than eight nodes, the eight-level
limit is reached, and the call is terminated.
Solution
Avoid the configuration of making the IVR process jump from node to node for more than eight times.
Matching mistake 1
Symptom
Configure the node to execute both normal secondary call by matching the number and extension
secondary call. When the subscriber dials 1201, the node does not execute the secondary call to the
number 7745231.
Following are the configurations:
[Sysname-voice-ivr] node 1 call
[Sysname-voice-ivr-node1] call-normal matching