R2511-HP MSR Router Series Voice Configuration Guide(V5)
37
Step Command Remarks
5. Configure the calling
name for the FXS voice
subscriber line.
calling-name text
Optional.
Not configured by default.
6. Configure the format of
messages (which carry the
calling number
information) transmitted
over the FXS voice
subscriber line.
cid type { complex | simple }
Optional.
The default is complex.
When the peer end supports only one
message format, you must use the same
message format at the local end as the
one used at the peer end.
7. Configure the standard for
the FXS voice subscriber
line to send messages
carrying the calling
number information.
cid standard-type { bellcore |
brazil }
Optional.
By default, bellcore is adopted.
Configuring packet loss compensation mode
Step Command Remarks
1. Enter system view.
System-view N/A
2. Enter FXS voice subscriber line
view.
subscriber-line line-number N/A
3. Configure the packet loss
compensation mode for the
FXS voice subscriber line.
plc-mode { general | specific }
Optional.
By default, the specific algorithm
provided by the voice gateway is
configured for the FXS voice
subscriber line.
Setting the electrical impedance
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter FXS voice subscriber line
view.
subscriber-line line-number N/A
3. Set the electrical impedance.
impedance { country-name | r550
| r600 | r650 | r700 | r750 |
r800 | r850 | r900 | r950 }
Optional.
By default, the electrical
impedance is the impedance value
applicable to China.
Configuring the sending of pulse signal at hangup
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter FXS voice subscriber line
view.
subscriber-line line-number N/A