R2511-HP MSR Router Series Voice Configuration Guide(V5)

79
Step Command Remarks
3. Create a TS set and enable R2
signaling for it.
timeslot-set ts-set-number timeslot-list
timeslots-list signal r2
N/A
4. Enter R2 CAS view.
cas ts-set-number N/A
5. Maintain the circuits of a
timeslot or a range of
timeslots.
ts { block | open | query | reset } timeslots
timeslots-list
Optional.
Configuring R2 digital line signaling
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter E1/T1 interface view.
controller { e1 | t1 } slot-number N/A
3. Create a TS set and enable R2
signaling for it.
timeslot-set ts-set-number
timeslot-list timeslots-list signal r2
N/A
4. Enter R2 CAS view.
cas ts-set-number N/A
5. Enable the terminating side to
send answer signal.
answer enable
Optional.
Enabled by default.
6. Enable the originating side to
support re-answer signal
processing.
re-answer enable
Optional.
By default, the originating side
does not support processing of
re-answer signals.
7. Enable the terminating side to
send clear-forward
acknowledgement signal
(clear-back signal).
clear-forward-ack enable
Optional.
Disabled by default.
8. Enable metering for R2
signaling.
force-metering enable
Optional.
Disabled by default.
9. Enable the terminating side to
send seizure
acknowledgement signal.
seizure-ack enable
Optional.
Enabled by default.
10. Configure the ABCD bit
pattern for each type of R2
line signal.
dl-bits { answer | blocking |
clear-back | clear-forward | idle |
seize | seizure-ack |
release-guard } { receive |
transmit } ABCD
Optional.
For more information, see Table
11.
11. Configure the C and D signal
bits.
renew ABCD
Optional.
N/A
12. Configure line signal
inversion mode.
reverse ABCD
Optional.
The default is 0000, that is, line
signal inversion disabled.