R2511-HP MSR Router Series Voice Configuration Guide(V5)

84
To configure the wink start mode:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter E1/T1 interface view.
controller { e1 | t1 } slot-number N/A
3. Create a TS set for digital
E&M signaling and select the
immediate start mode.
timeslot-set ts-set-number
timeslot-list timeslots-list signal
e&m-wink
N/A
4. Exit E1/T1 interface view.
quit N/A
5. Enter digital E&M voice
subscriber line view.
subscriber-line
slot-numbe:ts-set-number
N/A
6. Configure the maximum time
the calling party waits for
wink signal after sending the
seizure signal in wink start
mode.
delay wink-rising millseconds
Optional.
The default is 2,000 milliseconds.
7. Configure the maximum
duration of the wink signal
sent by the called party in
wink start mode.
delay wink-hold millseconds
Optional.
The default is 500 milliseconds.
8. Configure the minimum delay
the called party must wait
before sending a wink signal
in wink-start mode.
delay send-wink millseconds
Optional.
The default is 200 milliseconds.
Enabling E&M non-signaling mode
Analog E&M provides only one private line, which cannot meet the requirement of large-capacity private
lines. Therefore, digital E&M non-signaling should be supported by the VE1/VT1 interface. The calling
process is similar to that of analog E&M signaling except that digital signals are used instead of analog
signals. In this way, a VE1 interface can provide 30 private lines, and a VT1 interface can provide 23
private lines, thereby enlarging the system capacity.
This feature should be used with the PLAR function, you must also execute the private-line command on
the calling voice gateway. For more information about the PLAR function, see "Configuring dial plans."
Before you enable E&M non-signaling mode, E&M signaling must operate in immediate start mode.
For more information about the analog E&M non-signaling mode, see "Configuring E&M voice
su
bscriber line."
To enable E&M non-signaling mode:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter digital E&M voice subscriber
line view.
subscriber-line slot-number:
ts-set-number
N/A