HP MSR2000/3000/4000 Router Series Fundamentals Configuration Guide

49
Ste
p
Command
Remarks
5. Specify the number
of stop bits.
stopbits { 1 | 1.5 | 2 }
The default is 1.
Stop bits indicate the end of a character.
The more the stop bits, the slower the
transmission.
This command is not available in
console/AUX line class view.
6. Specify the number
of data bits for
each character.
databits { 5 | 6 | 7 | 8 }
The default is 8.
The setting depends on the character
coding type. For example, you can set it to
7 if standard ASCII characters are to be
sent, and set it to 8 if extended ASCII
characters are to be sent.
This command is not available in
console/AUX line class view.
7. Define a shortcut
key for starting a
terminal session.
activation-key character
By default, pressing Enter starts the
terminal session.
8. Define a shortcut
key for terminating
tasks.
escape-key { character | default }
By default, pressing Ctrl+C terminates a
task.
9. Configure the flow
control mode.
flow-control { hardware | none |
software }
flow-control hardware
flow-control-type1 [ software
flow-control-type2 ]
flow-control software
flow-control-type1 [ hardware
flow-control-type2 ]
These commands are not available in
console/AUX line class view.
10. Specify the
terminal display
type.
terminal type { ansi | vt100 }
By default, the terminal display type is
ANSI.
The device supports two terminal display
types: ANSI and VT100. HP recommends
that you set the display type to VT100 on
both the device and the configuration
terminal. If either side uses the ANSI type,
a display problem such as cursor
positioning error might occur when a
command line has more than 80
characters.
11. Set the maximum
number of lines to
be displayed on a
screen.
screen-length screen-length
By default, a screen displays 24 lines at
most.
A value of 0 disables pausing between
screens of output.
12. Set the size of the
command history
buffer.
history-command max-size value
By default, the buffer saves 10 history
commands at most.