HP MSR2000/3000/4000 Router Series High Availability Command Reference
52
Parameters
value: Specifies the multi-hop detection time multiplier in the range of 3 to 50.
Usage guidelines
The detection time multiplier determines the maximum number of concurrent BFD control packets that can
be discarded.
Table 14 sh
ows the detection interval calculation methods.
Table 14 Detection interval calculation method
Mode Detection interval
Control packet mode BFD session in
asynchronous mode
Detection time multiplier of the receiver × actual
packet sending interval of the receiver
Control packet mode BFD session in demand
mode
Detection time multiplier of the sender × actual
packet sending interval of the sender
Examples
# Configure the multi-hop detection time multiplier as 6.
<Sysname> system-view
[Sysname] bfd multi-hop detect-multiplier 6
bfd multi-hop min-receive-interval
Use bfd multi-hop min-receive-interval to configure the minimum interval for receiving multi-hop BFD
control packets.
Use undo bfd multi-hop min-receive-interval to restore the default.
Syntax
bfd multi-hop min-receive-interval value
undo bfd multi-hop min-receive-interval
Default
The minimum interval for receiving multi-hop BFD control packets is 1000 milliseconds.
Views
System view
Predefined user roles
network-admin
Parameters
value: Specifies the minimum interval for receiving multi-hop BFD control packets, in milliseconds. The
value range for this argument is 30 to 10000.
Usage guidelines
When the packet sending rate of the peer end exceeds the packet receiving capability (minimum control
packet receiving interval) of the local end, the peer end dynamically adjusts the BFD control packet
sending interval to the minimum control packet receiving interval of the local end.